Basic specifications (Accuracy guaranteed for 1 year, Post-adjustment accuracy guaranteed for 1 year)

32833283-20
AC Current10.00 m/ 100.0 m/ 1.000/ 10.00/ 200.0 A, 5 ranges, (40 Hz to 2 kHz, True RMS), Basic accuracy: ±1.0 % rdg. ±5 dgt., Guaranteed accuracy: from 1.00 mA
AC VoltageN/A
Frequency30.0 Hz to 1000 Hz, 2 ranges, Basic accuracy: ±0.3 % rdg. ±1 dgt.
Crest factor2.5 or less (1.5 at 200 A range)
Filter functionCut off frequency at filter ON: 180 Hz (-3dB)
OutputREC output for current: DC 1 V/f.s. (2 V/f.s. at only 200 A range), response time: less than 200 ms.
MON output for current: AC 1 V/f.s. (2 V/f.s. at only 200 A range), 5 Hz to 15 kHz frequency bandwidth (-3 dB)
N/A
Other functionsMax./ Min./ Average value record, Data hold, Auto power off
DisplayLCD, max. 2000 dgt., Display refresh rate: 4 times/s (Fast), 1 time/3s (Slow), 4 times/s (bar graph)
Power supply6LR61 (Stacked alkaline battery) ×1, or 6F22 (Stacked manganese battery), Continuous use: 40 hours (using 6F22), 
AC adapter 9445-02/-03
6LR61 (Stacked alkaline battery) ×1, or 6F22 (Stacked manganese battery), Continuous use: 40 hours (using 6F22)
Core jaw dia.φ 40 mm (1.57 in)
Dimensions and mass62 mm (2.44 in) W × 225 mm (8.86 in) H × 39 mm (1.54 in) D, 
400 g (14.1 oz)
AccessoriesCarrying case 9399 ×1, Hand strap ×1, Stacked manganese battery (6F22) ×1, Instruction manual ×1 

-------------------------------------------------------------------------------------------------------------------------------------------

PRODUCT

Loading...

MAKER

Product

Danh sách

Clamp-On Tester

Price: Call

Basic specifications (Accuracy guaranteed for 1 year, Post-adjustment accuracy guaranteed for 1 year)

32833283-20
AC Current10.00 m/ 100.0 m/ 1.000/ 10.00/ 200.0 A, 5 ranges, (40 Hz to 2 kHz, True RMS), Basic accuracy: ±1.0 % rdg. ±5 dgt., Guaranteed accuracy: from 1.00 mA
AC VoltageN/A
Frequency30.0 Hz to 1000 Hz, 2 ranges, Basic accuracy: ±0.3 % rdg. ±1 dgt.
Crest factor2.5 or less (1.5 at 200 A range)
Filter functionCut off frequency at filter ON: 180 Hz (-3dB)
OutputREC output for current: DC 1 V/f.s. (2 V/f.s. at only 200 A range), response time: less than 200 ms.
MON output for current: AC 1 V/f.s. (2 V/f.s. at only 200 A range), 5 Hz to 15 kHz frequency bandwidth (-3 dB)
N/A
Other functionsMax./ Min./ Average value record, Data hold, Auto power off
DisplayLCD, max. 2000 dgt., Display refresh rate: 4 times/s (Fast), 1 time/3s (Slow), 4 times/s (bar graph)
Power supply6LR61 (Stacked alkaline battery) ×1, or 6F22 (Stacked manganese battery), Continuous use: 40 hours (using 6F22), 
AC adapter 9445-02/-03
6LR61 (Stacked alkaline battery) ×1, or 6F22 (Stacked manganese battery), Continuous use: 40 hours (using 6F22)
Core jaw dia.φ 40 mm (1.57 in)
Dimensions and mass62 mm (2.44 in) W × 225 mm (8.86 in) H × 39 mm (1.54 in) D, 
400 g (14.1 oz)
AccessoriesCarrying case 9399 ×1, Hand strap ×1, Stacked manganese battery (6F22) ×1, Instruction manual ×1 

-------------------------------------------------------------------------------------------------------------------------------------------